| Error Code | Meaning | Safe first steps | Technician required | Related help |
|---|---|---|---|---|
| COMM ERR | Communication lost with the oven controller (L Series). | Reset the unit at the circuit breaker, turn power back on, and see whether the error returns. | Yes — if the error returns after reset. | |
| F1 | Door lock / unlock switches not sensed within 60 seconds while driving the door lock motor (L Series). | Reset the unit at the circuit breaker and test again in a bake mode. | Yes — if the error returns after reset. | |
| PROBE SHORTED | Temperature probe failure. | Replace the temperature probe if applicable, then reset power at the circuit breaker and retest. | Yes — if replacing the probe does not resolve the issue. | |
| 07 x 38 | MDL circuitry error (Legacy E Series). | Turn the home circuit breaker off for 10 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 10 0 0 | Communications error detected by the UIM (Legacy E Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 3311 | Upper or single oven TCO open (E Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 3222 | Lower oven RTD open (E Series). | No customer troubleshooting is published beyond contacting service. | Yes — immediate; official page gives no customer troubleshooting. | |
| 4021 | Bake element load missing for the upper or single oven (E Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 4221 | Broil element load missing for the upper or single oven (E Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 4A10 | Lower oven cooling fan HES stall detected (E Series). | No customer troubleshooting is published beyond contacting service. | Yes — immediate; official page gives no customer troubleshooting. | |
| 0021 | Bake element relay shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0222 | Lower bake element DLB shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0322 | Lower broil element relay shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0421 | Upper left convection element relay shorted (M Series). | Turn the home circuit breaker off for 10 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0422 | Lower left convection element relay shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0521 | Upper broil element DLB shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0821 | Upper MDL relay shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0931 / 0920 | Upper right convection fan triac shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 0932 / 0C20 | Lower right convection fan triac shorted (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 1121 | Upper right convection element relay open (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 2420 | Relay board RTD circuit fault (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. | |
| 6830 | UIP ambient thermistor circuit fault (M Series). | Turn the home circuit breaker off for 30 seconds, restore power, and retest oven operation. | Yes — if the error returns after reset. |
Wolf Wall Oven Error Codes That Disrupt Heating and Controls
Understand Wolf wall oven alerts involving door locking, temperature sensing, probe operation, MDL circuits, and communication between electronic controls. Review COMM ERR, F1, PROBE SHORTED, 07 x 38, 10 0 0, 3311, and 3222, then determine whether a breaker reset is appropriate or professional oven diagnosis is needed in San Diego.